Authors:
CARRASCO S
GONZALEZ R
JIMENEZ J
ROMAN R
MEDINA V
AZPIROZ J
Citation: S. Carrasco et al., COMPARISON OF THE HEART-RATE-VARIABILITY PARAMETERS OBTAINED FROM THEELECTROCARDIOGRAM AND THE BLOOD-PRESSURE WAVE, Journal of medical engineering & technology, 22(5), 1998, pp. 195-205
Authors:
PIERARDFRANCHIMONT C
NIKKELSTASSOUDJI N
LEFEBVRE P
PIERARD GE
Citation: C. Pierardfranchimont et al., SUBCLINICAL SKIN STIFFENING IN ADULTS SUFFERING FROM TYPE-1 DIABETES-MELLITUS - A COMPARISON WITH RAYNAUDS-SYNDROME, Journal of medical engineering & technology, 22(5), 1998, pp. 206-210
Citation: V. Suihko et H. Eskola, TRANSCRANIAL ELECTRICAL STIMULATOR PRODUCING HIGH AMPLITUDE PULSES AND PULSE TRAINS, Journal of medical engineering & technology, 22(5), 1998, pp. 211-215
Authors:
DONALDSON PEK
DONALDSON ND
RUSHTON DN
PERKINS TA
Citation: Pek. Donaldson et al., TECHNICAL NOTE - ESTIMATED ELECTRODE OPERATING-CONDITIONS OF THE FIRST LONDON MK V IMPLANTED STIMULATOR, Journal of medical engineering & technology, 22(5), 1998, pp. 216-219
Citation: J. Selfe, VALIDITY AND RELIABILITY OF MEASUREMENTS TAKEN BY THE PEAK-5 MOTION ANALYSIS SYSTEM, Journal of medical engineering & technology, 22(5), 1998, pp. 220-225
Citation: C. Rust et al., USING PRACTICE LED DESIGN RESEARCH TO DEVELOP AN ARTICULATED MECHANICAL ANALOGY OF THE HUMAN HAND, Journal of medical engineering & technology, 22(5), 1998, pp. 226-232
Authors:
CORDINGLEY JJ
PALAZZO MGA
THOMSON S
HYND J
CROSS BA
SEMPLE SJG
Citation: Jj. Cordingley et al., A FAST RESPONDING INTRAARTERIAL PH ELECTRODE FOR USE IN THE PERIPHERAL ARTERY OF ADULT HUMANS AND LARGE MAMMALS - A TECHNICAL DEVELOPMENT FOR USE IN RESEARCH, Journal of medical engineering & technology, 22(5), 1998, pp. 233-240
Citation: Oa. Lindahl et al., A TACTILE SENSOR FOR DETECTION OF PHYSICAL-PROPERTIES OF HUMAN SKIN IN-VIVO, Journal of medical engineering & technology, 22(4), 1998, pp. 147-153
Citation: Ca. Hajivassiliou, THE DEVELOPMENT AND EVOLUTION OF ARTIFICIAL URETHRAL SPHINCTERS, Journal of medical engineering & technology, 22(4), 1998, pp. 154-159
Authors:
UITERWAAL M
GLERUM EBC
BUSSER HJ
VANLUMMEL RC
Citation: M. Uiterwaal et al., AMBULATORY MONITORING OF PHYSICAL-ACTIVITY IN WORKING SITUATIONS, A VALIDATION-STUDY, Journal of medical engineering & technology, 22(4), 1998, pp. 168-172
Authors:
HEINONEN T
DASTIDAR P
ESKOLA H
FREY H
RYYMIN P
LAASONEN E
Citation: T. Heinonen et al., APPLICABILITY OF SEMIAUTOMATIC SEGMENTATION FOR VOLUMETRIC-ANALYSIS OF BRAIN-LESIONS, Journal of medical engineering & technology, 22(4), 1998, pp. 173-178
Citation: B. Blad et al., THE INFLUENCE OF THE MAGNETRON FREQUENCY, THE SERVO SETTINGS AND THE GANTRY ANGLE ON THE FLATNESS AND THE DOSE CALIBRATION OF A LINEAR-ACCELERATOR, Journal of medical engineering & technology, 22(4), 1998, pp. 185-188
Citation: Jj. Osullivan et al., VALIDATION OF THE TAKEDA-2421 AMBULATORY BLOOD-PRESSURE MONITOR IN CHILDREN, Journal of medical engineering & technology, 22(3), 1998, pp. 101-105
Authors:
MAGLAVERAS N
STAMKOPOULOS T
PAPPAS C
STRINTZIS M
Citation: N. Maglaveras et al., ECG PROCESSING TECHNIQUES BASED ON NEURAL NETWORKS AND BIDIRECTIONAL ASSOCIATIVE MEMORIES, Journal of medical engineering & technology, 22(3), 1998, pp. 106-111
Citation: Jh. Calderwood et Er. Mognaschi, A NOVEL FIELD FOR POSSIBLE USE IN MEDICAL IMPEDANCE TOMOGRAPHY, Journal of medical engineering & technology, 22(3), 1998, pp. 121-125
Authors:
KAUPPINEN P
HYTTINEN J
HEINONEN T
MALMIVUO J
Citation: P. Kauppinen et al., DETAILED MODEL OF THE THORAX AS A VOLUME CONDUCTOR BASED ON THE VISIBLE HUMAN MAN DATA, Journal of medical engineering & technology, 22(3), 1998, pp. 126-133
Citation: R. Agarwal, ULTRASONIC PARAMETERS OF RENAL CALCULI AND GALL-BLADDER STONES AS A FUNCTION OF DENSITY, Journal of medical engineering & technology, 22(3), 1998, pp. 134-136
Citation: T. Sugiura et al., A SELF-TUNING EFFECT OF MEMBERSHIP FUNCTIONS IN A FUZZY-LOGIC-BASED CARDIAC PACING SYSTEM, Journal of medical engineering & technology, 22(3), 1998, pp. 137-143
Citation: Dm. Mawson et Ac. Shore, COMPARISON OF CAPIFLOW AND FRAME BY FRAME ANALYSIS FOR THE ASSESSMENTOF CAPILLARY RED-BLOOD-CELL VELOCITY, Journal of medical engineering & technology, 22(2), 1998, pp. 53-63
Authors:
LAGUNA P
GARCIA J
RONCAL I
WAGNER G
LANDER P
MARK R
Citation: P. Laguna et al., MODEL-BASED ESTIMATION OF CARDIOVASCULAR REPOLARIZATION FEATURES - ISCHEMIA DETECTION AND PTCA MONITORING, Journal of medical engineering & technology, 22(2), 1998, pp. 64-72
Authors:
KAHLMEYER H
HAUSSLER C
LYNGSMO KO
BERG S
SCHIPPER KP
Citation: H. Kahlmeyer et al., RESULTS OF THE PERFORMANCE TESTING OF PURPOSE-BUILT AND PC-BASED ELECTROCARDIOGRAPHS USING A SIMPLE EVALUATION PROCEDURE, Journal of medical engineering & technology, 22(2), 1998, pp. 73-81