Citation: M. Malecki, Preparation of plasmid DNA in transfection complexes for fluorescence and electron spectroscopic imaging, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 1-16
Citation: Gv. Childs, Simultaneous identification of a specific gene protein product and transcript using combined immunocytochemistry and in situ hybridization with non-radioactive probes, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 17-26
Citation: Le. De Bault et J. Gu, In situ hybridization, in situ transcription, and in situ polymerase chainreaction, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 27-47
Citation: Gw. Konat, Generation of high efficiency ssDNA hybridization probes by linear polymerase chain reaction (LPCR), SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 57-60
Authors:
Heim, M
Eschrich, R
Hillebrand, A
Knapp, HF
Cevc, G
Guckenberger, R
Citation: M. Heim et al., Hydration-scanning tunneling microscopy as a reliable method for imaging biological specimens and hydrophilic insulators, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 73-80
Citation: R. Lal, Imaging molecular structure of channels and receptors with an atomic forcemicroscope, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 81-96
Authors:
Lyubchenko, YL
Blankenship, RE
Gall, AA
Lindsay, SM
Thiemann, O
Simpson, L
Shlyakhtenko, LS
Citation: Yl. Lyubchenko et al., Atomic force microscopy of DNA, nucleoproteins and cellular complexes: Theuse of functionalized substrates, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 97-109
Citation: T. Muller-reichert et H. Gross, Microscopic analysis of DNA and DNA-protein assembly by transmission electron microscopy, scanning tunneling microscopy and scanning force microscopy, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 111-121
Authors:
Allen, TD
Bennion, GR
Rutherford, SA
Reipert, S
Ramalho, A
Kiseleva, E
Goldberg, MW
Citation: Td. Allen et al., Accessing nuclear structure for field emission, in lens, scanning electronmicroscopy (FEISEM), SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 149-164
Citation: At. Sumner, Problems in preparation of chromosomes for scanning electron microscopy toreveal morphology and to permit immunocytochemistry of sensitive antigens, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 165-176
Citation: Ns. Allen et Mn. Bennett, Electro-optical imaging of F-actin and endoplasmic reticulum in living andfixed plant cells, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 177-187
Citation: Sm. Potter et al., Neural transplant staining with DiI and vital imaging by 2-photon laser-scanning microscopy, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 189-199
Citation: P. Vesely et A. Boyde, Video rate confocal laser scanning reflection microscopy in the investigation of normal and neoplastic living cell dynamics, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 201-211
Authors:
Braet, F
De Zanger, R
Kalle, W
Raap, A
Tanke, H
Wisse, E
Citation: F. Braet et al., Comparative scanning, transmission and atomic force microscopy of the microtubular cytoskeleton in fenestrated liver endothelial cells, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 225-236
Citation: Ld. Peachey et al., Correlated confocal and intermediate voltage electron microscopy imaging of the same cells using sequential fluorescence labeling, fixation, and critical point dehydration, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 237-247
Citation: E. Ralston et T. Ploug, Pre-embedding staining of single muscle fibers for light and electron microscopy studies of subcellular organization, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 249-260
Authors:
Marijianowski, MMH
Teeling, P
Dingemans, KP
Becker, AE
Citation: Mmh. Marijianowski et al., Multiple labeling in electron microscopy: Its application in cardiovascular research, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 261-271
Citation: Dr. Swartz, Covalent labeling of proteins with fluorescent compounds for imaging applications, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 273-284
Authors:
Bohn, W
Etzrodt, D
Foisner, R
Wiche, G
Traub, P
Citation: W. Bohn et al., Cytoskeleton architecture of C6 rat glioma cell subclones whole mount electron microscopy and immunogold labeling, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 285-294
Citation: L. Edelmann et A. Ruf, Freeze-dried human leukocytes stabilized with uranyl acetate during low temperature embedding or with OsO4 vapor after embedding, SCANNING MICROSCOPY SUPPLEMENT 10, 1996, 1996, pp. 295-307