Citation: Psm. Barbour et al., A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups, P I MEC E H, 214(H6), 2000, pp. 569-576
Citation: Mt. Raimondi et al., A method for the evaluation of the change in volume of retrieved acetabular cups, P I MEC E H, 214(H6), 2000, pp. 577-587
Authors:
Bibb, R
Freeman, P
Brown, R
Sugar, A
Evans, P
Bocca, A
Citation: R. Bibb et al., An investigation of three-dimensional scanning of human body surfaces and its use in the design and manufacture of prostheses, P I MEC E H, 214(H6), 2000, pp. 589-594
Citation: W. Xu et al., Finite element analysis of bone stress and strain around a distal osseointegrated implant for prosthetic limb attachment, P I MEC E H, 214(H6), 2000, pp. 595-602
Citation: M. Kellomaki et al., Pliable polylactide plates for guided bone regeneration: manufacturing andin vitro, P I MEC E H, 214(H6), 2000, pp. 615-629
Citation: Nj. Dunne et Jf. Orr, Development of a computer model to predict pressure generation around hip replacement stems, P I MEC E H, 214(H6), 2000, pp. 645-658
Citation: A. Asundi et A. Kishen, Stress distribution in the dento-alveolar system using digital photoelasticity, P I MEC E H, 214(H6), 2000, pp. 659-667
Citation: L. Yang et al., The effects of different wire and screw combinations on the stiffness of ahybrid external fixator, P I MEC E H, 214(H6), 2000, pp. 669-676
Citation: Zm. Jin, A general axisymmetric contact mechanics model for layered surfaces, with particular reference to artificial hip joint replacements, P I MEC E H, 214(H5), 2000, pp. 425-435
Citation: He. Ash et al., Long-term results for Kinemax and Kinematic knee bearings on a six-stationknee wear simulator, P I MEC E H, 214(H5), 2000, pp. 437-447
Authors:
Moorcroft, CI
Thomas, PBM
Ogrodnik, PJ
Verborg, SA
Citation: Ci. Moorcroft et al., A device for improved reduction of tibial fractures treated with external fixation, P I MEC E H, 214(H5), 2000, pp. 449-457
Citation: Gh. Isaac et al., Radiographic assessment of the cement mantle thickness of the femoral stemin total hip replacement: a case study of 112 consecutive implants, P I MEC E H, 214(H5), 2000, pp. 471-477
Citation: Nm. Sudharsan et Eyk. Ng, Parametric optimization for tumour identification bioheat equation using ANOVA and the Taguchi method, P I MEC E H, 214(H5), 2000, pp. 505-512
Authors:
Bell, J
Besong, AA
Tipper, JL
Ingham, E
Wroblewski, BM
Stone, MH
Fisher, J
Citation: J. Bell et al., Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations, P I MEC E H, 214(H5), 2000, pp. 513-518
Citation: S. Syngellakis et al., Assessment of the non-linear behaviour of plastic ankle foot orthoses by the finite element method, P I MEC E H, 214(H5), 2000, pp. 527-539