Authors:
TANABE K
BELOHLAVEK M
JAKRAPANICHAKUL D
BAE RY
GREENLEAF JF
SEWARD JB
Citation: K. Tanabe et al., 3-DIMENSIONAL ECHOCARDIOGRAPHY - PRECISION AND ACCURACY OF LEFT-VENTRICULAR VOLUME MEASUREMENT USING ROTATIONAL GEOMETRY WITH VARIABLE NUMBERS OF SLICE RESOLUTION, Echocardiography, 15(6), 1998, pp. 575-580
Authors:
MACLELLANTOBERT SG
BUITHIEU J
BELOHLAVEK M
BEHRENBECK T
GREENLEAF JF
EDWARDS WD
SEWARD JB
Citation: Sg. Maclellantobert et al., 3-DIMENSIONAL IMAGING USED FOR VIRTUAL DISSECTION, IMAGE BANKING AND PHYSICAL REPLICATION OF ANATOMY AND PHYSIOLOGY, Echocardiography, 15(1), 1998, pp. 89-98
Authors:
BELOHLAVEK M
TANABE K
MULVAGH SL
FOLEY DA
GREENLEAF JF
SEWARD JB
Citation: M. Belohlavek et al., IMAGE-ENHANCEMENT BY NONCONTRAST HARMONIC ECHOCARDIOGRAPHY - PART II - QUANTITATIVE ASSESSMENT WITH USE OF CONTRAST-TO-SPECKLE RATIO, Mayo Clinic proceedings, 73(11), 1998, pp. 1066-1070
Authors:
JAKRAPANICHAKUL D
BELOHLAVEK M
TANABE K
BAE RY
BREEN JF
GREENLEAF JF
SEWARD JB
Citation: D. Jakrapanichakul et al., RAPID 3-DIMENSIONAL ECHOCARDIOGRAPHY - LEFT-VENTRICULAR VOLUME MEASUREMENT IN PATIENTS COMPARED TO ELECTRON-BEAM COMPUTED-TOMOGRAPHY, Circulation, 98(17), 1998, pp. 1009-1009
Authors:
BAE RY
BELOHLAVEK M
TANABE K
GREENLEAF JF
SEWARD JB
Citation: Ry. Bae et al., MEASUREMENT OF AT RISK MYOCARDIUM IN ACUTE MYOCARDIAL-INFARCTION USING TEXTURE ANALYSIS AND A NEURAL-NETWORK ON MYOCARDIAL CONTRAST ECHOCARDIOGRAPHIC IMAGES, Circulation, 98(17), 1998, pp. 2990-2990
Citation: M. Belohlavek et al., MULTIPARAMETRIC ECHOCARDIOGRAPHY - A NEW CONCEPT FOR NONINVASIVE ASSESSMENT OF MYOCARDIAL VIABILITY, Circulation, 98(17), 1998, pp. 4101-4101
Citation: Y. Zheng et al., REDUCTION OF BREAST BIOPSIES WITH A MODIFIED SELF-ORGANIZING MAP, IEEE transactions on neural networks, 8(6), 1997, pp. 1386-1396
Authors:
BELOHLAVEK M
MACLELLANTOBERT SG
SEWARD JB
GREENLEAF JF
Citation: M. Belohlavek et al., TOROIDAL GEOMETRY - NOVEL 3-DIMENSIONAL INTRACARDIAC IMAGING WITH A PHASED-ARRAY TRANSDUCER, Journal of the American Society of Echocardiography, 10(5), 1997, pp. 493-498
Authors:
BELOHLAVEK M
FOSTER SM
KINNICK RR
GREENLEAF JF
SEWARD JB
Citation: M. Belohlavek et al., REFERENCE TECHNIQUES FOR LEFT-VENTRICULAR VOLUME MEASUREMENT BY 3-DIMENSIONAL ECHOCARDIOGRAPHY - DETERMINATION OF PRECISION, ACCURACY, AND FEASIBILITY, Echocardiography, 14(4), 1997, pp. 329-335
Citation: M. Belohlavek et Jf. Greenleaf, DETECTION OF CARDIAC BOUNDARIES IN ECHOCARDIOGRAPHIC IMAGES USING A CUSTOMIZED ORDER-STATISTICS FILTER (VOL 19, PG 127, 1997), Ultrasonic imaging, 19(3), 1997, pp. 234-234
Citation: M. Belohlavek et Jf. Greenleaf, DETECTION OF CARDIAC BOUNDARIES IN ECHOCARDIOGRAPHIC IMAGES USING A CUSTOMIZED ORDER-STATISTICS FILTER, Ultrasonic imaging, 19(2), 1997, pp. 127-137
Citation: Zy. Jiang et al., ANALYTIC INVESTIGATION OF CHAOS IN A CLASS OF PARABOLIC RAY SYSTEMS, The Journal of the Acoustical Society of America, 101(4), 1997, pp. 1971-1980
Citation: Y. Zheng et Jf. Greenleaf, THE EFFECT OF CONCAVE AND CONVEX WEIGHT ADJUSTMENTS ON SELF-ORGANIZING MAPS, IEEE transactions on neural networks, 7(1), 1996, pp. 87-96
Citation: Me. Allam et Jf. Greenleaf, ISOMORPHISM BETWEEN PULSED-WAVE DOPPLER ULTRASOUND AND DIRECTION-OF-ARRIVAL ESTIMATION .1. BASIC PRINCIPLES, IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 43(5), 1996, pp. 911-922