Authors:
Stein, H
Perren, SM
Mosheiff, R
Baumgart, F
Cordey, J
Citation: H. Stein et al., Decline in transfixing K-wire tension of the circular external fixator: Experimental continuous in vivo measurements, ORTHOPEDICS, 24(10), 2001, pp. 985-989
Authors:
Schneider, E
Michel, MC
Genge, M
Zuber, K
Ganz, R
Perren, SM
Citation: E. Schneider et al., Loads acting in an intramedullary nail during fracture healing in the human femur, J BIOMECHAN, 34(7), 2001, pp. 849-857
Authors:
Hertel, R
Eijer, H
Meisser, A
Hauke, C
Perren, SM
Citation: R. Hertel et al., Biomechanical and biological considerations relating to the clinical use of the Point Contact-Fixator - Evaluation of the device handling test in thetreatment of diaphyseal fractures of the radius and/or ulna, INJURY, 32, 2001, pp. SB10-SB14
Authors:
Eijer, H
Hauke, C
Arens, S
Printzen, G
Schlegel, U
Perren, SM
Citation: H. Eijer et al., PC-Fix and local infection resistance - Influence of implant design on postoperative infection development, clinical and experimental results, INJURY, 32, 2001, pp. SB38-SB43
Authors:
Haas, N
Hauke, C
Schutz, M
Kaab, M
Perren, SM
Citation: N. Haas et al., Treatment of diaphyseal fractures of the forearm using the Point Contact Fixator (PC-Fix): Results of 387 fractures of a prospective multicentric study (PC-Fix II), INJURY, 32, 2001, pp. SB51-SB62
Authors:
Muller, CA
Baumgart, F
Wahl, D
Perren, SM
Pfister, U
Citation: Ca. Muller et al., Technical innovations in medullary reaming: Reamer design and intramedullary pressure increase, J TRAUMA, 49(3), 2000, pp. 440-445
Citation: Dc. Ayotte et al., Direction-dependent constriction flow in a poroelastic solid: The intervertebral disc valve, J BIOMECH E, 122(6), 2000, pp. 587-593
Citation: U. Knothe et al., Development and testing of a new self-locking intramedullary nail system: testing of handling aspects and mechanical properties, INJURY, 31(8), 2000, pp. 617-626
Citation: J. Cordey et al., Stress protection due to plates: Myth or reality? A parametric analysis made using the composite beam theory, INJURY, 31, 2000, pp. 1-13
Citation: E. Gautier et al., Effect of plate position relative to bending direction on the rigidity of a plate osteosynthesis. A theoretical analysis, INJURY, 31, 2000, pp. 14-20
Citation: J. Cordey et al., Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws and the friction between plate and bone, INJURY, 31, 2000, pp. 21-28
Authors:
Borgeaud, M
Cordey, J
Leyvraz, PF
Perren, SM
Citation: M. Borgeaud et al., Mechanical analysis of the bone to plate interface of the LC-DCP and of the PC-FIX on human femora, INJURY, 31, 2000, pp. 29-36
Authors:
Arens, S
Kraft, C
Schlegel, U
Printzen, G
Perren, SM
Hansis, M
Citation: S. Arens et al., Susceptibility to local infection in biological internal fixation - Experimental study of open vs minimally invasive plate osteosynthesis in rabbits, ARCH ORTHOP, 119(1-2), 1999, pp. 82-85
Authors:
Arens, S
Eijer, H
Schlegel, U
Printzen, G
Perren, SM
Hansis, M
Citation: S. Arens et al., Influence of the design for fixation implants on local infection: Experimental study of dynamic compression plates versus point contact fixators in rabbits, J ORTHOP TR, 13(7), 1999, pp. 470-476