AAAAAA

   
Results: 1-25 |
Results: 25

Authors: LAUBACH C RATHGEBER J OSER A PALUMBO S
Citation: C. Laubach et al., MICROBIOLOGY OF THE SWINE HEAD MEAT DEBONING PROCESS, Journal of food protection, 61(2), 1998, pp. 249-252

Authors: RATHGEBER J ZUCHNER K
Citation: J. Rathgeber et K. Zuchner, BREATHING SYSTEM FILTERS AND HEPATITIS-C, Anaesthesia and intensive care, 26(2), 1998, pp. 219-220

Authors: RATHGEBER J BURCHARDI H
Citation: J. Rathgeber et H. Burchardi, USE OF THE ANTIBIOTIC ERYTHROMYCIN IN INTESTINAL ATONY, Anaesthesist, 47(6), 1998, pp. 523-524

Authors: HEISE D RATHGEBER J KETTLER D
Citation: D. Heise et al., SOURCES OF FAULTS AND DANGERS IN THE USE OF SYRINGE DRIVERS - ACCIDENTAL OCCLUSION OF THE INFUSION SYSTEM, Anasthesist, 47(1), 1998, pp. 54-58

Authors: RATHGEBER J SCHORN B FALK V KAZMAIER S VONSPIEGEL T BURCHARDI H
Citation: J. Rathgeber et al., THE INFLUENCE OF CONTROLLED MANDATORY VENTILATION (CMV), INTERMITTENTMANDATORY VENTILATION (IMV) AND BIPHASIC INTERMITTENT POSITIVE AIRWAYPRESSURE (BIPAP) ON DURATION OF INTUBATION AND CONSUMPTION OF ANALGESICS AND SEDATIVES - A PROSPECTIVE ANALYSIS IN 596 PATIENTS FOLLOWING ADULT CARDIAC-SURGERY, European journal of anaesthesiology, 14(6), 1997, pp. 576-582

Authors: RATHGEBER J KIETZMANN D MERGERYAN H HUB R ZUCHNER K KETTLER D
Citation: J. Rathgeber et al., PREVENTION OF PATIENT BACTERIAL-CONTAMINATION OF ANESTHESIA-CIRCLE-SYSTEMS - A CLINICAL-STUDY OF THE CONTAMINATION RISK AND PERFORMANCE OF DIFFERENT HEAT AND MOISTURE EXCHANGERS WITH ELECTRET FILTER (HMEF), European journal of anaesthesiology, 14(4), 1997, pp. 368-373

Authors: SCHIFFMANN H RATHGEBER J SINGER D HARMS K BOLLI A ZUCHNER K
Citation: H. Schiffmann et al., AIRWAY HUMIDIFICATION IN MECHANICALLY VENTILATED NEONATES AND INFANTS- A COMPARATIVE-STUDY OF A HEAT AND MOISTURE EXCHANGER VS. A HEATED HUMIDIFIER USING A NEW FAST-RESPONSE CAPACITIVE HUMIDITY SENSOR, Critical care medicine, 25(10), 1997, pp. 1755-1760

Authors: DIEDRICH U BITSCH A EICKE M RATHGEBER J PRANGE HW
Citation: U. Diedrich et al., GAMMA-HYDROXYBUTYRATE IN THE TREATMENT OF INCREASED INTRACRANIAL-PRESSURE AND VASOSPASM, Aktuelle Neurologie, 23(2), 1996, pp. 63-67

Authors: PANZER W BRETTHAUER M KLINGLER H BAHR J RATHGEBER J KETTLER D
Citation: W. Panzer et al., ACD VERSUS STANDARD CPR IN A PREHOSPITAL SETTING, Resuscitation, 33(2), 1996, pp. 117-124

Authors: RATHGEBER J PANZER W GUNTHER U SCHOLZ M HOEFT A BAHR J KETTLER D
Citation: J. Rathgeber et al., INFLUENCE OF DIFFERENT TYPES OF RECOVERY POSITIONS ON PERFUSION INDEXES OF THE FOREARM, Resuscitation, 32(1), 1996, pp. 13-17

Authors: KETTLER D BAHR J RATHGEBER J PURSCHKE R
Citation: D. Kettler et al., THE SITUATION OF ANESTHESIA IN MIDDLE AND EAST EUROPA, Anasthesiologie und Intensivmedizin, 37(4), 1996, pp. 219-224

Authors: RATHGEBER J WEYLAND W BETTKA T ZUCHNER K KETTLER D
Citation: J. Rathgeber et al., HEATED HUMIDIFIERS AND HEAT AND MOISTURE EXCHANGERS IN THE TREATMENT OF PERIOPERATIVE HEAT-LOSS AND REWARMING OF HYPOTHERMIC PATIENTS - HEAT AND MOISTURE EXCHANGERS VS ACTIVE HUMIDIFIERS IN THE VENTILATED LUNGMODEL, Anasthesist, 45(9), 1996, pp. 807-813

Authors: RATHGEBER J HENZE D ZUCHNER K
Citation: J. Rathgeber et al., AIR-CONDITIONING USING A HIGH-PERFORMANCE HEAT AND MOISTURE EXCHANGER(HME) - AN EFFECTIVE AND ECONOMICAL ALTERNATIVE TO ACTIVE HUMIDIFIERSIN MECHANICALLY VENTILATED PATIENTS - A PROSPECTIVE, RANDOMIZED CLINICAL-STUDY, Anasthesist, 45(6), 1996, pp. 518-525

Authors: RATHGEBER J
Citation: J. Rathgeber, HEAT AND MOISTURE EXCHANGERS FOR HUMIDIFY ING THE INSPIRED AIR OF INTUBATED PATIENTS IN INTENSIVE-CARE MEDICINE - RESPONSE, Anasthesist, 45(3), 1996, pp. 286-287

Authors: RATHGEBER J HENZE D ZUCHNER K
Citation: J. Rathgeber et al., RESPIRATORY GAS CLIMATIZATION WITH HEAT A ND MOISTURE EXCHANGER - AN EFFECTIVE AND LOW-COST ALTERNATIVE TO ACTIVE HUMIDIFICATION SYSTEMS FOR VENTILATED PATIENTS - REPLY, Anasthesist, 45(12), 1996, pp. 1271-1272

Authors: SCHMIDT JH WEYLAND W FRITZ U BRAUER A RATHGEBER J BRAUN U
Citation: Jh. Schmidt et al., EFFICACY OF DIFFERENT INFUSION AND BLOOD- WARMING METHODS - AN EXPERIMENTAL-MODEL, Anasthesist, 45(11), 1996, pp. 1067-1074

Authors: HEISE D RATHGEBER J BURCHARDI H
Citation: D. Heise et al., SEVERE ACCIDENTAL HYPOTHERMIA - ACTIVE RE WARMING WITH A SIMPLE EXTRACORPOREAL VENOVENOUS WARMING-CIRCUIT - CASE-REPORT, Anasthesist, 45(11), 1996, pp. 1093-1096

Authors: WEYLAND W SCHUHMANN M RATHGEBER J WEYLAND A FRITZ U LAIERGROENEVELD G SCHORN B BRAUN U
Citation: W. Weyland et al., OXYGEN COST OF BREATHING FOR ASSISTED SPONTANEOUS BREATHING MODES - INVESTIGATION INTO 3 STATES OF PULMONARY-FUNCTION, Intensive care medicine, 21(3), 1995, pp. 211-217

Authors: WEYLAND W RATHGEBER J KAZMAIER S TROSTDORF U TEXTOR Z FRITZ U BRAUN U
Citation: W. Weyland et al., POSTOPERATIVE WARMING IN CARDIO-SURGICAL PATIENTS, British Journal of Anaesthesia, 74, 1995, pp. 17-17

Authors: RATHGEBER J ZUCHNER K KIETZMANN D KRAUS E
Citation: J. Rathgeber et al., EFFICIENCY, ARGON ACCUMULATION, AND ACCUR ACY OF ANESTHETIC GAS MONITORING DURING MECHANICAL VENTILATION IN A CIRCLE SYSTEM USING AN OXYGENCONCENTRATOR, Anasthesist, 44(9), 1995, pp. 643-650

Authors: RATHGEBER J ZUCHNER K KIETZMANN D WEYLAND W
Citation: J. Rathgeber et al., HEAT AND MOISTURE EXCHANGERS FOR HUMIDIFY ING THE INSPIRED AIR OF INTUBATED PATIENTS IN INTENSIVE-CARE MEDICINE - AN INVESTIGATION OF HUMIDIFICATION PROPERTIES OF HEAT AND MOISTURE EXCHANGERS UNDER CLINICAL CONDITIONS, Anasthesist, 44(4), 1995, pp. 274-283

Authors: KLOCKGETHERRADKE A RATHGEBER J LANGE H
Citation: A. Klockgetherradke et al., INADVERTENT INTRACARDIAC ENTRAPMENT OF A SWAN-GANZ CATHETER, Anasthesist, 44(2), 1995, pp. 116-118

Authors: KIETZMANN D FOTH H GENG WP RATHGEBER J GUNDERTREMY U KETTLER D
Citation: D. Kietzmann et al., TRANSPULMONARY DISPOSITION OF PRILOCAINE, MEPIVACAINE, AND BUPIVACAINE IN HUMANS IN THE COURSE OF EPIDURAL-ANESTHESIA, Acta anaesthesiologica Scandinavica, 39(7), 1995, pp. 885-890

Authors: RATHGEBER J
Citation: J. Rathgeber, RESPIRATORS IN INTENSIVE-CARE MEDICINE - BASIC INFORMATION, Anasthesist, 42(6), 1993, pp. 396-417

Authors: RATHGEBER J
Citation: J. Rathgeber, FUNDAMENTALS OF ANESTHESIA MACHINES AND V ENTILATORS, Anasthesist, 42(12), 1993, pp. 885-909
Risultati: 1-25 |