AAAAAA

   
Results: 1-14 |
Results: 14

Authors: DOLOGLOU I VANHUFFEL S VANORMONDT D
Citation: I. Dologlou et al., FREQUENCY-SELECTIVE MRS DATA QUANTIFICATION WITH FREQUENCY PRIOR KNOWLEDGE, Journal of magnetic resonance [1997], 130(2), 1998, pp. 238-243

Authors: DOLOGLOU I VANHUFFEL S VANORMONDT D
Citation: I. Dologlou et al., IMPROVED SIGNAL ENHANCEMENT PROCEDURES APPLIED TO EXPONENTIAL DATA MODELING, IEEE transactions on signal processing, 45(3), 1997, pp. 799-803

Authors: GRAVERONDEMILLY D MARSEILLE GJ CREMILLIEUX Y CAVASSILA S VANORMONDT D
Citation: D. Graverondemilly et al., SRS-FT, A FOURIER-IMAGING METHOD BASED ON SPARSE RADIAL SCANNING AND BAYESIAN-ESTIMATION, Journal of magnetic resonance. Series B, 112(2), 1996, pp. 119-123

Authors: MARSEILLE GJ DEBEER R FUDERER M MEHLKOPF AF VANORMONDT D
Citation: Gj. Marseille et al., NONUNIFORM PHASE-ENCODE DISTRIBUTIONS FOR MRI SCAN TIME REDUCTION, Journal of magnetic resonance. Series B, 111(1), 1996, pp. 70-75

Authors: CHEN H VANHUFFEL S VANORMONDT D DEBEER R
Citation: H. Chen et al., PARAMETER-ESTIMATION WITH PRIOR KNOWLEDGE OF KNOWN SIGNAL POLES FOR THE QUANTIFICATION OF NMR-SPECTROSCOPY DATA IN THE TIME-DOMAIN, Journal of magnetic resonance. Series A, 119(2), 1996, pp. 225-234

Authors: VONDRA V VANDENBOOGAART A GRAVERONDEMILLY D VANORMONDT D
Citation: V. Vondra et al., AUTOMATIC ESTIMATION OF THE TIME ORIGIN AND OVERALL PHASE OF AN FID SIGNAL, Journal of magnetic resonance. Series A, 119(2), 1996, pp. 271-274

Authors: OVERLOOP K VANHECKE P VANSTAPEL F CHEN H VANHUFFEL S KNIJN A VANORMONDT D
Citation: K. Overloop et al., EVALUATION OF SIGNAL-PROCESSING METHODS FOR THE QUANTIFICATION OF A MULTIEXPONENTIAL SIGNAL - THE GLYCOGEN C-13-1 NMR SIGNAL, NMR in biomedicine, 9(7), 1996, pp. 315-321

Authors: DOLOGLOU I VANORMONDT D CARAYANNIS G
Citation: I. Dologlou et al., MRI SCAN TIME REDUCTION THROUGH NONUNIFORM SAMPLING AND SVD-BASED ESTIMATION, Signal processing, 55(2), 1996, pp. 207-219

Authors: DEBEER R MARSEILLE GJ MEHLKOPF AF VANORMONDT D WAJER FTAW
Citation: R. Debeer et al., MODELING OF MEDICAL MAGNETIC-RESONANCE-IMAGING SIGNALS, IEE proceedings. Vision, image and signal processing, 141(1), 1994, pp. 71-75

Authors: DECANNIERE C VANHECKE P VANSTAPEL F CHEN H VANHUFFEL S VANDERVOORT C VANTONGEREN B VANORMONDT D
Citation: C. Decanniere et al., EVALUATION OF SIGNAL-PROCESSING METHODS FOR THE QUANTIFICATION OF STRONGLY OVERLAPPING PEAKS IN P-31 NMR-SPECTRA, Journal of magnetic resonance. Series B, 105(1), 1994, pp. 31-37

Authors: MARSEILLE GJ FUDERER M DEBEER R MEHLKOPF AF VANORMONDT D
Citation: Gj. Marseille et al., REDUCTION OF MRI SCAN TIME THROUGH NONUNIFORM SAMPLING AND EDGE-DISTRIBUTION MODELING, Journal of magnetic resonance. Series B, 103(3), 1994, pp. 292-295

Authors: DEBEER R VANORMONDT D
Citation: R. Debeer et D. Vanormondt, BACKGROUND FEATURES IN MAGNETIC-RESONANCE SIGNALS - ADDRESSED BY SVD-BASED STATE-SPACE MODELING, Applied magnetic resonance, 6(3), 1994, pp. 379-390

Authors: DEBEER R MICHELS F VANORMONDT D VANTONGEREN BPO LUYTEN PR VANVROONHOVEN H
Citation: R. Debeer et al., REDUCED LIPID CONTAMINATION IN IN-VIVO H-1 MRSI USING TIME-DOMAIN FITTING AND NEURAL-NETWORK CLASSIFICATION, Magnetic resonance imaging, 11(7), 1993, pp. 1019-1026

Authors: KNIJN A DEBEER R VANORMONDT D
Citation: A. Knijn et al., FREQUENCY-SELECTIVE QUANTIFICATION IN THE TIME DOMAIN, Journal of magnetic resonance, 97(2), 1992, pp. 444-450
Risultati: 1-14 |