Citation: M. Zangeneh et al., ON THE DESIGN CRITERIA FOR SUPPRESSION OF SECONDARY FLOWS IN CENTRIFUGAL AND MIXED-FLOW IMPELLERS, Journal of turbomachinery, 120(4), 1998, pp. 723-735
Authors:
MAGOMETSCHNIGG D
BRANDT D
HOFMANN R
SIHORSCH K
STOSCHITZKY K
ZANGENEH M
ZENKER G
Citation: D. Magometschnigg et al., TREATMENT OF LEFT-VENTRICULAR HYPERTROPHY IN HYPERTENSIVE PATIENTS WITH A COMBINATION OF VERAPAMIL AND CAPTOPRIL - A MULTICENTER STUDY, International journal of clinical pharmacology and therapeutics, 35(9), 1997, pp. 389-396
Authors:
BINDER T
REHAK G
PORENTA G
ZANGENEH M
MAURER G
BAUMGARTNER H
Citation: T. Binder et al., POTENTIAL OF DIGITAL ECHOCARDIOGRAPHY DESCRIPTION OF A LEARNING TOOL FOR ECHOCARDIOGRAPHY, Acta anaesthesiologica Scandinavica, 41, 1997, pp. 279-280
Citation: M. Zangeneh et al., SUPPRESSION OF SECONDARY FLOWS IN A MIXED-FLOW PUMP IMPELLER BY APPLICATION OF 3-DIMENSIONAL INVERSE DESIGN METHOD .1. DESIGN AND NUMERICALVALIDATION, Journal of turbomachinery, 118(3), 1996, pp. 536-543
Citation: A. Goto et al., SUPPRESSION OF SECONDARY FLOWS IN A MIXED-FLOW PUMP IMPELLER BY APPLICATION OF 3-DIMENSIONAL INVERSE DESIGN METHOD .2. EXPERIMENTAL VALIDATION, Journal of turbomachinery, 118(3), 1996, pp. 544-551
Citation: M. Zangeneh, INVERSE DESIGN OF CENTRIFUGAL-COMPRESSOR VANED DIFFUSERS IN INLET SHEAR FLOWS, Journal of turbomachinery, 118(2), 1996, pp. 385-393
Authors:
BINDER T
GLOBITS S
ZANGENEH M
GABRIEL H
ROTHY W
KOLLER J
GLOGAR D
Citation: T. Binder et al., 3-DIMENSIONAL ECHOCARDIOGRAPHY USING A TRANSESOPHAGEAL IMAGING PROBE - POTENTIALS AND TECHNICAL CONSIDERATIONS, European heart journal, 17(4), 1996, pp. 619-628
Authors:
BINDER T
GLOBITS S
ZANGENEH M
GABRIEL H
ROTHY W
GLOGAR D
MAURER G
BAUMGARTNER H
Citation: T. Binder et al., VALUE OF 3-DIMENSIONAL ECHOCARDIOGRAPHY AS AN ADJUNCT TO CONVENTIONALTRANSESOPHAGEAL ECHOCARDIOGRAPHY, Cardiology, 87(4), 1996, pp. 335-342
Citation: F. Ghobadi et al., FREE FAT AUTOTRANSPLANTATION FOR THE COSMETIC TREATMENT OF FIRST WEB SPACE ATROPHY, Annals of plastic surgery, 35(2), 1995, pp. 197-200
Authors:
GABRIEL H
BINDER T
GLOBITS S
ZANGENEH M
ROTHY W
GLOGAR D
Citation: H. Gabriel et al., 3-DIMENSIONAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF POSTINFARCTION VENTRICULAR SEPTAL-DEFECT, The American heart journal, 129(5), 1995, pp. 1038-1040
Citation: M. Zangeneh, INVISCID-VISCOUS INTERACTION METHOD FOR 3-DIMENSIONAL INVERSE DESIGN OF CENTRIFUGAL IMPELLERS, Journal of turbomachinery, 116(2), 1994, pp. 280-290
Authors:
BINDER T
GABRIEL H
GLOBITS S
KOLLER J
ZANGENEH M
ROTHY W
GLOGAR D
Citation: T. Binder et al., DYNAMIC 3-DIMENSIONAL IMAGING OF MITRAL-VALVE PATHOLOGIES USING ECHO-CT, Journal of the American College of Cardiology, 1994, pp. 10000175-10000175