Sp. Gavrilov et Aa. Vertiy, APPLICATION OF TOMOGRAPHY METHOD IN MILLIMETER WAVELENGTHS BAND .1. THEORETICAL, International journal of infrared and millimeter waves, 18(9), 1997, pp. 1739-1760
Tomographic methods of image recomstruction of two-dimensional cross-s
ections of volumetric objects in millimeter wavelengths band are sugge
sted and considered. It is shown that in the frequency band under cons
ideration, the images of investigated objects may be obtained by first
-order diffraction tomography method (Born, Rytov or high frequency ap
proximation of the first-order for scattered electromagnetic field).