IMPROVEMENT OF GC-MS ANALYSIS OF ORGANOCHLORINE PESTICIDES IN SEDIMENTS BY USE OF A COMPUTER-OPTIMIZED TEMPERATURE PROGRAM

Citation
H. Pichler et al., IMPROVEMENT OF GC-MS ANALYSIS OF ORGANOCHLORINE PESTICIDES IN SEDIMENTS BY USE OF A COMPUTER-OPTIMIZED TEMPERATURE PROGRAM, Fresenius' journal of analytical chemistry, 359(3), 1997, pp. 293-297
Citations number
15
Categorie Soggetti
Chemistry Analytical
ISSN journal
09370633
Volume
359
Issue
3
Year of publication
1997
Pages
293 - 297
Database
ISI
SICI code
0937-0633(1997)359:3<293:IOGAOO>2.0.ZU;2-5
Abstract
A simulation and optimization software program (Pro ezGC(R) by Analyti cal Innovations, Inc., Kettering, OH, USA) for GC temperature programs was applied to the analysis of organochlorine pesticides in sediments . By means of this software, the run time of a conventional temperatur e program derived from trial and error experiments could be reduced to less than a third, achieving at the same time an increased separation efficiency. Finally, 17 organochlorine pesticides could be baseline-r esolved on a capillary column in less than 12 min. In addition, a two- fold sensitivity enhancement was achieved.