USE OF TRACK DETECTORS IN BIOMEDICAL SCIENCES

Citation
A. Waheed et al., USE OF TRACK DETECTORS IN BIOMEDICAL SCIENCES, Nuclear tracks & radiation measurements, 22(1-4), 1993, pp. 889-892
Citations number
11
Categorie Soggetti
Nuclear Sciences & Tecnology
ISSN journal
09698078
Volume
22
Issue
1-4
Year of publication
1993
Pages
889 - 892
Database
ISI
SICI code
0969-8078(1993)22:1-4<889:UOTDIB>2.0.ZU;2-4
Abstract
The CR-39 track detectors have been applied to irradiate the Chinese h amster V79-753B cells for survival studies. The survival curves have g iven satisfactory results. Energies of the incoming as well as outgoin g proton beams evaluated from the track diameters are found to be clos e to the values found separately by surface barrier detector (SSBD).