A reproducible method for measuring the redox potential of wines using
platinum electrodes was developed involving a consistent electrode pr
etreatment and carefully controlled experimental conditions. Reproduci
bility favoured platinized electrodes (+/- 3mV), over unplatinized ele
ctrodes (+/- 6 mV), while poisoning was found to have a greater effect
on platinized electrodes. However, the dependence of the potential up
on the degree of platinization indicated that both platinized and unpl
atinized electrodes should be used to maximize the information obtaine
d about the redox state of a wine. A linear relationship was observed
between the potential and pH of 26 wines tested, particularly on plati
nized electrodes. The measured potentials are discussed in terms of mi
xed potential theory and the influence of adsorbates.