The paper describes tests carried out on large scale reinforced concre
te test units with details modeling those encountered in sections of L
os Angeles' 1-10 Santa Monica Viaduct. Lap-splices of column longitudi
nal reinforcement, and joint details including inadequate development
of column reinforcement in the cap beam and a total absence of special
joint reinforcement would be considered unacceptable in new designs.
The purpose of the tests was to obtain verification of analytical pred
ictions that, despite the poor detailing the bents, could be expected
to survive the design level earthquake without collapse. Test;results
confirmed that the lap splices should perform adequately under seismic
attack, and the column/cap beam connections would maintain gravity lo
ad capacity after joint degradation.