C. Sanchezbrunete et al., DETERMINATION OF RESIDUES OF PHENOXY ACID HERBICIDES IN SOIL AND CEREALS BY GAS-CHROMATOGRAPHY ION-TRAP DETECTION, Journal of chromatography, 675(1-2), 1994, pp. 213-218
The analysis of several phenoxy acids in soil and cereals was carried
out by gas chromatography with ion trap detection, after derivatizatio
n with BF3-methanol. Soil was extracted with methylene chloride, at ac
idic pH, on an orbit shaker, and plants were extracted with a 0.1 M Na
OH solution in a Sorvall homogenizer. The extracts were cleaned up by
liquid-liquid partition, the organic solvents evaporated and residues
methylated. Herbicides residues were determined by gas chromatography-
ion trap detection on a BP-1 capillary column with helium as carrier g
as. Recovery through the method was studied in the range of 0.2 to 2 m
u g/g and was found higher than 80% for each herbicide in both matrixe
s. Residues of phenoxy acids were determined by selecting the base pea
k of their spectra, after acquisition of the total-ion chromatogram of
the sample. The limit of detection in the selected-ion mode was 0.005
mu g/g in soil and 0.04 mu g/g in plant samples.