BALLOON DILATATION OF THE PULMONARY VALVE IN A PATIENT WITH PULMONARYATRESIA AND INTACT VENTRICULAR SEPTUM USING A COMMERCIALLY AVAILABLE RADIOFREQUENCY CATHETER

Citation
T. Akagi et al., BALLOON DILATATION OF THE PULMONARY VALVE IN A PATIENT WITH PULMONARYATRESIA AND INTACT VENTRICULAR SEPTUM USING A COMMERCIALLY AVAILABLE RADIOFREQUENCY CATHETER, Pediatric cardiology, 18(1), 1997, pp. 61-63
Citations number
5
Categorie Soggetti
Cardiac & Cardiovascular System",Pediatrics
Journal title
ISSN journal
01720643
Volume
18
Issue
1
Year of publication
1997
Pages
61 - 63
Database
ISI
SICI code
0172-0643(1997)18:1<61:BDOTPV>2.0.ZU;2-6
Abstract
Using a commercially available 5F deflectable radiofrequency catheter, we have succeeded in percutaneous valvotomy of an imperforate pulmona ry valve and consecutive balloon dilatation in a baby with pulmonary a tresia and intact ventricular septum. After the procedure, right ventr icular systolic pressure fell from 125 mmHg to 65 mmHg, and right vent riculography demonstrated anterograde blood flow into the pulmonary ar teries. There were no major complications. Doppler echocardiography at 1 year after the procedure demonstrated a pressure gradient across th e pulmonary valve of 20 mmHg with mild pulmonary and tricuspid regurgi tations.