POROSITY OF ELECTROLESS NICKEL COATINGS INVESTIGATED USING DIFFERENT POROSITY TESTS AND THEIR APPLICATION

Citation
P. Ernst et al., POROSITY OF ELECTROLESS NICKEL COATINGS INVESTIGATED USING DIFFERENT POROSITY TESTS AND THEIR APPLICATION, Transactions of the Institute of Metal Finishing, 75, 1997, pp. 194-198
Citations number
19
Categorie Soggetti
Metallurgy & Metallurigical Engineering","Materials Science, Coatings & Films
ISSN journal
00202967
Volume
75
Year of publication
1997
Part
5
Pages
194 - 198
Database
ISI
SICI code
0020-2967(1997)75:<194:POENCI>2.0.ZU;2-R
Abstract
The porosity of electroless nickel coatings on mild steel substrates h aving different substrate surface roughness and coating thickness was investigated using NSS (Neutral Salt Spray), ferroxyl, and SO2 tests. In addition the influence of substrate surface roughness and coating t hickness upon the properties of electroless nickel coatings was studie d. It was found that all porosity tests showed the same tendency for t he porosity of electroless nickel coatings to decrease with decreasing substrate surface roughness and increasing coating thickness. The use of the SO2 and ferroxyl test have the advantage over the NSS test as a routine quality control procedure in that they are both quicker to c arry out and easier to interpret. A relationship between porosity, sub strate surface roughness and coating thickness was established which m ight be used as an industrial quality control tool.