Se. Kentish et al., MEASUREMENT OF DROP RISE VELOCITIES WITHIN A KUHNI EXTRACTION COLUMN, Industrial & engineering chemistry research, 36(11), 1997, pp. 4928-4933
A new method is presented for the determination of droplet rise veloci
ties within liquid-liquid extraction columns. This method utilizes the
difference between the static drop size distribution as measured by a
photographic technique and the dynamic drop size distribution as meas
ured by a capillary probe technique. The ratio of the two volume densi
ties multiplied by the average flow velocity is then a direct measure
of the individual drop velocity. Droplet velocities measured using thi
s technique are consistent with single drop velocities measured by oth
er workers at low holdups. However, at higher holdups the droplet velo
cities converge toward a single value rather than retaining a range of
drop size dependent values.