Hm. Abdelhamid et al., EFFECT OF ION-BOMBARDMENT ON THE TL-RESPONSE OF BOTH LIF (TLD-100) AND A HOME-MADE LIF-MG,CU,P PHOSPHORS, Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 132(1), 1997, pp. 119-122
In this article, a comparative dosimetric study is used on two types o
f phosphors; the standard LiF (TLD-100) and a home-made LIF : ME,Cu,P
to show that ion beam bombardment may be a useful tool in the study an
d improvement of radiation sensitive materials. In the bombardment pro
cess, either oxygen ion (chemically active) or argon ion (chemically i
nert) was used, having energy of 4 keV and 3 flux of 21 x 10(13) ions
cm(-2) s(-1) and the obtained results were compared with each other. I
t has been found that the sensitivity of the home-made LIF : Mg,Cu,P h
as got a maximum of similar to+40% when pre-treated for 5 min with arg
on ion beam. Meanwhile the sensitivity for the standard LiF (TLD-100)
phosphor has got a maximum of similar to+20% when pre-treated with oxy
gen ion for 10 min. (C) 1997 Elsevier Science B.V.