L. Paama et al., SPECTROCHEMICAL AND THERMAL-ANALYSIS OF AL-TETRABROMOPHTHALATE AND TETRABROMOPHTHALIC ANHYDRIDE - A COMPARISON OF METHODS FOR DETERMINATIONOF ALUMINUM, Talanta, 45(1), 1997, pp. 35-38
A sequential inductively coupled plasma atomic emission spectrometer (
ICP-AES) was used to determine Al content in Al-tetrabromophthalate (A
l-TBP). Four emission lines of Al (I) at 309.271, 396.152, 308.215 and
394.401 nm were compared. The microwave mineralisation was carried ou
t by using a two-step digestion procedure and HNO3-H2SO4. The thermal
analysis of Al-TBP and tetrabromophthalic anhydride (TBPA) was perform
ed in the air atmosphere. Statistical tests applied (t-test, F-test) s
howed no significant differences between the Al results obtained by IC
P-AES and thermal method of analysis. (C) 1997 Elsevier Science B.V.