ISSUES OF MEASURING THE PRIMARY CRYSTALLITES SIZE IN POWDER, AIR SUSCEPTIBLE MATERIALS

Citation
B. Dvorak et al., ISSUES OF MEASURING THE PRIMARY CRYSTALLITES SIZE IN POWDER, AIR SUSCEPTIBLE MATERIALS, Applied catalysis. A, General, 162(1-2), 1997, pp. 261-268
Citations number
6
Categorie Soggetti
Chemistry Physical","Environmental Sciences
ISSN journal
0926860X
Volume
162
Issue
1-2
Year of publication
1997
Pages
261 - 268
Database
ISI
SICI code
0926-860X(1997)162:1-2<261:IOMTPC>2.0.ZU;2-H
Abstract
Analysis of time stability of the profile of(1 1 1)Cu diffraction line in an activated carrier catalyst CHEROX 46-00 has been used in testin g the quality of a cuvette for XRD analysis of samples containing a co mponent unstable in air. It was found that the described type of cuvet te can provide a distorted information about the size of primary cryst allites of analyzed phase if the time stability of sample is not known . New method for protecting the active component of sample in the cuve tte against air oxygen was worked out and experimentally tested. The m ethod provides a high time stability of this type of samples for XRD a nalysis. It consists in the surface protection of an unstable solid ph ase with a laminar liquid film of a suitable non-reactive sorbate (e.g ., 2-ethylhexanol) and in the analysis of sample in a pasty form. The efficiency of sample stabilization is a function of the content of dis persing liquid in the analyzed paste. (C) 1997 Elsevier Science B.V.