TIME RESPONSE ANALYSIS OF A PYROELECTRIC DETECTOR

Citation
Fy. Chen et al., TIME RESPONSE ANALYSIS OF A PYROELECTRIC DETECTOR, Ferroelectrics, 200(1-4), 1997, pp. 257-268
Citations number
12
Categorie Soggetti
Physics, Condensed Matter","Material Science
Journal title
ISSN journal
00150193
Volume
200
Issue
1-4
Year of publication
1997
Pages
257 - 268
Database
ISI
SICI code
0015-0193(1997)200:1-4<257:TRAOAP>2.0.ZU;2-K
Abstract
The pyroelectric time response of a pyroelectric detector is calculate d as a function of film thickness, the volume specific heat and therma l conductivity. It is found that the thinner the pyroelectric layer is , the faster the time response is and the larger the response amplitud e is, and that the thinner the absorbing layer is, the faster the time response is and the larger the response amplitude; however, the effec t of the absorbing layer thickness is lower than that of the pyroelect ric layer thickness. Though the thinner the pyroelectric layer is, the better the pyroelectric response is, in reality, the tunneling curren t (i.e., leakage current) increases with decreasing the pyroelectric l ayer thickness and this is forbidden in some applications. In this pap er, we propose two models to analyze the thermal conduction. The fit i s quite well compared with the experimental result.