APPLICATION OF DB-5MS GAS-CHROMATOGRAPHY COLUMN FOR THE COMPLETE ASSIGNMENT OF 2,3,7,8-SUBSTITUTED POLYCHLORODIBENZO-P-DIOXINS AND POLYCHLORODIBENZOFURANS IN SAMPLES FROM MUNICIPAL WASTE INCINERATOR EMISSIONS
E. Abad et al., APPLICATION OF DB-5MS GAS-CHROMATOGRAPHY COLUMN FOR THE COMPLETE ASSIGNMENT OF 2,3,7,8-SUBSTITUTED POLYCHLORODIBENZO-P-DIOXINS AND POLYCHLORODIBENZOFURANS IN SAMPLES FROM MUNICIPAL WASTE INCINERATOR EMISSIONS, Journal of chromatography, 786(1), 1997, pp. 125-134
Citations number
9
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
The analysis of polychlorodibenzo-p-dioxins (PCDDs) and polychlorodibe
nzofurans (PCDFs) using four different gas chromatography (GC) columns
(DB-5, DB-5ms, DB-DIOXIN and Cp-Sil 88) for the correct assignment an
d accurate determination of the 2,3,7,8-chloro-substituted isomers to
attain the limit value of 0.1 ng I-TEF/Nm(3) (I-TEF=International Toxi
c Equivalent Factor) for the municipal waste incinerator (MWI) emissio
ns is described. The DB-Sms GC column allows improvements in the analy
sis of PCDDs and PCDFs, especially for several toxic isomers which coe
lute with interfering compounds on DB-5, DB-DIOXIN or Cp-Sil ss GC col
umns, such as 2,3,7,8-TCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,7,8-PeCDD or 1,2,
3,7,8,9-HxCDD. In fact, the results indicated that the column allows t
he correct assignment of fourteen toxic isomers. However, separation o
f 1,2,3,7,8-PeCDF or 2,3,4,7,8-PeCDF and 1,2,3,7,8,9-HxCDF shows inter
ferences, which are critical. (C) 1997 Elsevier Science B.V.