ION ENERGY SPREAD AND CURRENT MEASUREMENTS OF THE RF-DRIVEN MULTICUSPION-SOURCE

Citation
Y. Lee et al., ION ENERGY SPREAD AND CURRENT MEASUREMENTS OF THE RF-DRIVEN MULTICUSPION-SOURCE, Review of scientific instruments, 68(3), 1997, pp. 1398-1402
Citations number
9
Categorie Soggetti
Physics, Applied","Instument & Instrumentation
ISSN journal
00346748
Volume
68
Issue
3
Year of publication
1997
Pages
1398 - 1402
Database
ISI
SICI code
0034-6748(1997)68:3<1398:IESACM>2.0.ZU;2-6
Abstract
Axial energy spread and useful beam current of positive ion beams have been carried out using a radio frequency (rf)-driven multicusp ion so urce. Operating the source with a 13.56 MHz induction discharge, the a xial energy spread is found to be approximately 3.2 eV. The extractabl e beam current of the rf-driven source is found to be comparable to th at of filament-discharge sources. With a 0.6 mm diameter extraction ap erture, a positive hydrogen ion beam current density of 80 mA/cm(2) ca n be obtained at a rf input power of 2.5 kW. The expected source lifet ime is much longer than that of filament discharges. (C) 1997 American Institute of Physics.