V. Hormazabal et M. Yndestad, DETERMINATION OF DIFLUBENZURON AND TEFLUBENZURON IN FISH FEED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, Journal of liquid chromatography & related technologies, 20(7), 1997, pp. 1115-1121
Citations number
11
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
A simple method for the determination of diflubenzuron and teflubenzur
on in fish feed by HPLC is presented. The samples were extracted with
acetone - tetrahydrofurane and diluted with tetrahydrofurane, prior to
the HPLC. The lower limit of quantification was 0.25 and 0.4 g/kg. fo
r diflubenzuron and teflubenzuron in fish feed, respectively.