Polysilicon microfracture specimens were fabricated using surface micr
omachining techniques identical to those used to fabricate microelectr
omechanical systems (MEMS) devices. The nominal critical J-integral (t
he critical energy release rate) for crack initiation, J(c), was deter
mined in specimens whose characteristic dimensions were of the same or
der of magnitude as the grain size of the polysilicon. J(c) values ran
ged from 16 to 62 N/m, approximately a factor of four larger than J(c)
values reported for single crystal silicon.