Sy. Lee et Sm. Morgano, REPAIR OF POSTERIOR BASE OF A MAXILLARY COMPLETE DENTURE BY USE OF A CAST OF STONE AND RESILIENT MATERIAL, The Journal of prosthetic dentistry, 74(5), 1995, pp. 546-548
A method to repair a fractured complete denture and simultaneously aug
ment deficient borders or correct an inadequate posterior palatal seal
is described. Corrections were made intraorally with modeling compoun
d and an elastomeric impression material. A resilient impression mater
ial was used to block out the undercuts in the denture, and repair was
accomplished with visible Light-cured resin or an autopolymerizing re
pair resin. This technique simplifies the laboratory procedures and th
ereby permits the return of the denture to the patient at the same vis
it.