The performance of ten seismic beam-to-column moment connection specim
ens using bolted web-welded flanges (BWWF) detail is critically assess
ed. Key parameters include: beam flange to entire section plastic modu
lus ratio, Z(F)/Z, supplemental web bolts, supplemental web welds and
column panel zone strength. It was found that the cyclic plastic rotat
ional capacities of the BWWF connections ranged between 0.009 and 0.01
8 rad, and did not indicate apparent relationships with respect to the
beam section modulus ratios. The ultimate beam flange flexural streng
th, Z(F)F(u), well predicted the ultimate moment capacities of BWWF co
nnections. Using the proposed strength criterion, the supplemental web
welds, but not the supplemental web bolts, significantly enhance the
strength, ductility and energy absorbing capacity of the BWWF connecti
ons.