M. Tago et al., FORCED-CONVECTION FREEZING CHARACTERISTICS ALONG THE CONVEX WALL OF ARETURN BEND WITH RECTANGULAR CROSS-SECTION, Experimental thermal and fluid science, 11(4), 1995, pp. 311-320
An experimental study was made of the forced convection freezing chara
cteristics on the convex wall of a return bend with a rectangular cros
s section. Observations were carried out for duct heights of 17 and 30
mm, a duct width of 300 mm, and a radius of curvature of 159 mm. The
convex wall temperature was uniformly maintained below the freezing te
mperature of water, and the concave wall was insulated. It was found t
hat a stepwise ice layer forms on the convex wall of a return bend and
that the step position at the steady-state condition is closely depen
dent on both the water flow velocity and the cooling temperature ratio
.