H. Namirskakrzton et al., ENZYME-LINKED ANTIGLOBULIN-TEST FOR THE EVALUATION OF THE AMOUNT OF IGG AUTOANTIBODIES ON RED-BLOOD-CELLS, Clinical and laboratory haematology, 17(3), 1995, pp. 221-224
An enzyme-linked antiglobulin test (FLAT) was adapted to the assessmen
t of IgG autoantibodies on red cells. Due to the worked out standard c
urve and the performance of the test on microplates, ELAT became a sim
ple and inexpensive technique. It can be used for the detection of IgG
within the range from 70 to 37,500 molecules per red cell. This is a
simple quantitative method that can be used in immunohaematological st
udies of red cells.