HEAT-TRANSFER IN NATURAL CIRCULATION CLOSED-LOOP THERMOSIPHON

Authors
Citation
M. Kamil et Ss. Alam, HEAT-TRANSFER IN NATURAL CIRCULATION CLOSED-LOOP THERMOSIPHON, INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 3(1), 1996, pp. 1-6
Citations number
NO
Categorie Soggetti
Chemistry Applied","Engineering, Chemical
ISSN journal
0971457X
Volume
3
Issue
1
Year of publication
1996
Pages
1 - 6
Database
ISI
SICI code
0971-457X(1996)3:1<1:HINCCT>2.0.ZU;2-2
Abstract
Experiments have been performed with distilled water, methanol, benzen e, toluene and ethylene glycol at atmospheric pressure to measure the average heat transfer coefficient under natural convection conditions. Uniform heat flux values have been used in the range of 4.1-43.0 kW/m (2), while inlet liquid subcooling of 0.5-11.6 degrees C. The typical experimental data have been presented graphically. An empirical correl ation for the average Nusselt number has also been developed.