The power generated by the proposed Indian MHD retrofit channel has be
en evaluated under different operating conditions. Coal is used as a w
orking fuel, and the various properties of the combustion gases have b
een calculated using a computer program based on the principle of Gibb
's free energy. The effects of operating conditions, e.g. loading para
meters, input pressure and temperature, magnetic field, etc. on the ou
tput characteristic have been studied in detail, taking into account t
he various losses inside the MHD channel. Based on these studies, some
optimum working conditions for the MHD retrofit channel have been sug
gested.