INTERACTION COEFFICIENTS FOR 15 MIXTURES OF FLAMMABLE AND NON-FLAMMABLE COMPONENTS

Citation
Dr. Defibaugh et G. Morrison, INTERACTION COEFFICIENTS FOR 15 MIXTURES OF FLAMMABLE AND NON-FLAMMABLE COMPONENTS, International journal of refrigeration, 18(8), 1995, pp. 518-523
Citations number
4
Categorie Soggetti
Engineering, Mechanical",Thermodynamics
ISSN journal
01407007
Volume
18
Issue
8
Year of publication
1995
Pages
518 - 523
Database
ISI
SICI code
0140-7007(1995)18:8<518:ICF1MO>2.0.ZU;2-#
Abstract
Bubble pressures were measured for 15 binary mixtures, each composed m ainly of one flammable and one non-flammable component. The mixtures w ere trichlorofluoromethane + isopentane, pentafluoroethane + 1,1,1-tri fluoroethane, 1,1-dichloro-2,2,2-trifluoroethane + {1,1-dichloro-1-flu oroethane or isopentane}, 1,1,1,2-tetrafluoroethane + {1,1-difluoroeth ane or propane or cyclopropane or isobutane}, difluoromethane + {penta fluoroethane or 1,1,1,2-tetrafluoroethane or 1, 1-difluoroethane}. Als o studied were mixtures of 1,1-difluoroethane + {cyclopropane or propa ne or butane or isobutane}, which compromise two flammable components, The measurements were made at approximately equimolar compositions us ing either a vapour-liquid equilibrium apparatus over a range of tempe ratures, or a static pressure measurement at 273.15K. The bubble press ures were used to determine interaction coefficients that characterize the non-ideal behaviour of these fluid mixtures. The interaction coef ficients are used in equation-of-state models for the thermodynamic pr operties of refrigerant mixtures.