Abstract
The third level trigger of the L3 experiment has been upgraded to cope with the high luminosity currently reached at LEP (similar to 1.4 . 1 0(31)cm(-2)s(-1)). The new hardware implementation is based on a farm of four VAXstations 4000/90, which receive data through FASTBUS to SCS I interfaces and send accepted events to the main online computer via FDDI. A new software architecture, which makes extensive use of VMS in terprocess communication tools, has been built. The current filter alg orithms, briefly described here, ensure an output rate of less than 1. 5 Hz (in addition to the events used to measure the luminosity) with a very low background contamination. The trigger efficiency, studied wi th the leptonic Z decays, is 100%.