A. Jankowski et H. Lamparczyk, EVALUATION OF CHROMATOGRAPHIC METHODS FOR THE DETERMINATION OF NIFEDIPINE IN HUMAN SERUM, Journal of chromatography, 668(2), 1994, pp. 469-473
Gas-liquid chromatography and high-performance liquid chromatography w
ere compared for the identification and determination of nifedipine in
biological samples and the elaboration of the optimum liquid-liquid e
xtraction procedure. The determination limits were 2 and 10 ng/ml, res
pectively, and the detection limits were 1 and 5 ng/ml, respectively.
The calibration graphs were linear in the ranges 2-300 and 10-500 ng/m
l, respectively. Recoveries based on three different concentrations we
re 88.7-95.8% and 93.7-104.2%, respectively. Both methods are sensitiv
e, specific and reproducible enough for pharmacokinetic studies and th
erapeutic drug monitoring.