SIZE-EXCLUSION CHROMATOGRAPHY STUDY ON THE TETRAETHYL ORTHOSILICATE SOL-GEL DERIVED SYSTEM

Authors
Citation
J. Retuert, SIZE-EXCLUSION CHROMATOGRAPHY STUDY ON THE TETRAETHYL ORTHOSILICATE SOL-GEL DERIVED SYSTEM, Boletin de la Sociedad Chilena de Quimica, 40(4), 1995, pp. 415-419
Citations number
20
Categorie Soggetti
Chemistry
ISSN journal
03661644
Volume
40
Issue
4
Year of publication
1995
Pages
415 - 419
Database
ISI
SICI code
0366-1644(1995)40:4<415:SCSOTT>2.0.ZU;2-H
Abstract
The formation of polysiloxanes during controlled hydrolysis of tetraet hyl orthosilicate has been studied by size exclusion chromatography. T he reactions were carried out with a relative low quantity of water in ethanol or tetrahydrofuran as solvents and using either closed or ope n systems. It was found that the polymerization proceeds more rapidly in an open container using ethanol as solvent.