A study of 120 total hip replacements showed the advantages of the var
iable vacuum drainage system over the continuous high vacuum drainage
system, Better wound healing, less severe hematomas and less occlusion
of drains confirmed the higher effectiveness of secretion draining, W
ith regard to hygienic aspects, and especially to wound infection, the
continuous closed drainage system is an improvement of the intermitte
nt closed drainage system.