In order to support a Joint ICRP/ICRU Task Group action aiming at the
collection of data of interest in the field of radiation protection, t
he EURADOS Working Group 4 'Numerical Dosimetry' has initiated a compu
tational programme for the determination of fluence-to-absorbed-dose o
r dose-equivalent conversion coefficients for slab phantoms irradiated
by external electrons of normal and oblique incidence, Seven experts
in electron transport simulations agreed to contribute to the project.
Using different code systems, they provided new data in the energy ra
nge between 60 keV and 10 MeV for three slab phantoms consisting of 4-
element ICRU tissue, water and PMMA, at depths of 0.007 g.cm(-2), 0.3
g.cm(-2) and 1.0 g.cm(-2). From those data, reference conversion coeff
icients were derived for each depth. This paper summarises the main fe
atures of the detailed data analysis subsequently performed on the dif
ferent sets of numerical values, and extensively described in PTB Repo
rt Dos-24.