An efficient and simple non-linear active control method called Bounde
d-Force Control (BFC) method has been developed. The theoretical devel
opment and application examples of the BFC method has been presented i
n several publications(1-3) where it was shown that the BFC is more ef
ficient than the Linear Quadratic Regulator (LQR) method in terms of m
aximum control force and power requirements when applied to an Active
Tuned Mass Damper (ATMD) system. Following a brief review of the funda
mental concept of the BFC and a discussion of its main advantages, the
results of an experimental investigation using a three-storey shear b
uilding model excited by a shaking table and controlled by an electrom
agnetic linear motor are presented. The experimental results were in p
erfect agreement with the analytical results, thus confirming the vali
dity of the proposed BFC algorithm.