A combined experimental and analytical investigation was conducted to
evaluate a heat pipe convective cooling device consisting of sixteen s
mall copper/water heat pipes mounted vertically in a 4 x 4 array which
was 25.4 mm square. The analytical portion of the investigation focus
ed on determination of the maximum heat transport capacity and the res
istance of the individual heat pipes. The resistance of each heat pipe
was found to be 2.51 K/Watt, or more than 3 times smaller than the re
sistance produced by a solid copper rod with the same dimensions. The
maximum predicted heat rejection for the module was over 50 Watts, or
a power density in excess of 7.75 Watts/cm(2). In the experimental por
tion of the investigation, two different modules were tested. The firs
t module utilized ten circular aluminum fins mounted on the condenser
end of each heat pipe to enhance heat rejection, while the second cont
ained only the sixteen copper/water heat pipes. The effects of flow ve
locity, input power, and base plate temperature on the overall thermal
resistance and the heat rejection capacity were determined as well as
the pressure drop resulting from each module. The finned heat pipe ar
ray was found to have a lower overall thermal resistance and thus, a h
igher heat rejection capacity, bur also resulted in a significantly la
rger pressure drop than the array without fins. The results of the hea
t pipe array experiments were also compared with experimental and empi
rical results obtained from flow over a flat plate 25.4 mm square.