P. Lander et al., ANALYSIS OF HIGH-RESOLUTION ECG-CHANGES DURING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY, Journal of electrocardiology, 28, 1995, pp. 39-40
The authors have hypothesized that low-level, electrocardiographic cha
nges may accompany transient ischemia induced by percutaneous translum
inal coronary angioplasty. Altered repolarization may manifest as subc
linical changes in ST-T morphology. Changes in depolarization may mani
fest as low-amplitude notches and slurs, a phenomenon the authors term
abnormal intra-QRS potentials. The initial aim of this study was to c
haracterize changes in high-resolution electrocardiograph signals that
might be linked to ischemic involvement of the ventricular myocardium
.