Flja. Dewijs et al., FRONT TOOTH REPLACEMENT WITH TUBINGEN (FRIALIT(R)) IMPLANTS - A RADIOGRAPHICAL EVALUATION, Journal of oral rehabilitation, 23(2), 1996, pp. 97-100
A total of 214 radiographs of 76 Tubingen implants placed in the anter
ior region of the maxillae of 56 patients were evaluated by two observ
ers. The first radiographs were taken after implant placement (n = 76)
. The second set of radiographs were taken during months 13-23 (n = 53
), the third during the months 24-35 (n = 28), the fourth during month
s 36-47 (n = 15), the fifth during months 48-59 (n = 18) and the sixth
during months 60-72 (n = 20). Only four radiographs were available af
ter longer periods, namely the eight and the ten year of function. The
two observers together classified the marginal bone height (mesial an
d distal) as 0 (no resorption) or 1-5 in steps of 2.5 mm resorption. A
score of 1 represents marginal bone resorption less than 2.5 nm, 2 fr
om 2.5 mm to 5 mm, 3 from 5 to 7.5 mm, 4 from 7.5 to 10 mm and 5 more
than 10 mm loss of marginal bone height. Thirty-six implants scored ma
rginal bone height of 0 or 1. Twenty-two implants scored not higher th
an 2. Eight implants scored bone loss up to 3, four up to 4 and one up
to 5. Five implants were lost.