FRONT TOOTH REPLACEMENT WITH TUBINGEN (FRIALIT(R)) IMPLANTS - A RADIOGRAPHICAL EVALUATION

Citation
Flja. Dewijs et al., FRONT TOOTH REPLACEMENT WITH TUBINGEN (FRIALIT(R)) IMPLANTS - A RADIOGRAPHICAL EVALUATION, Journal of oral rehabilitation, 23(2), 1996, pp. 97-100
Citations number
3
Categorie Soggetti
Dentistry,Oral Surgery & Medicine
ISSN journal
0305182X
Volume
23
Issue
2
Year of publication
1996
Pages
97 - 100
Database
ISI
SICI code
0305-182X(1996)23:2<97:FTRWT(>2.0.ZU;2-Q
Abstract
A total of 214 radiographs of 76 Tubingen implants placed in the anter ior region of the maxillae of 56 patients were evaluated by two observ ers. The first radiographs were taken after implant placement (n = 76) . The second set of radiographs were taken during months 13-23 (n = 53 ), the third during the months 24-35 (n = 28), the fourth during month s 36-47 (n = 15), the fifth during months 48-59 (n = 18) and the sixth during months 60-72 (n = 20). Only four radiographs were available af ter longer periods, namely the eight and the ten year of function. The two observers together classified the marginal bone height (mesial an d distal) as 0 (no resorption) or 1-5 in steps of 2.5 mm resorption. A score of 1 represents marginal bone resorption less than 2.5 nm, 2 fr om 2.5 mm to 5 mm, 3 from 5 to 7.5 mm, 4 from 7.5 to 10 mm and 5 more than 10 mm loss of marginal bone height. Thirty-six implants scored ma rginal bone height of 0 or 1. Twenty-two implants scored not higher th an 2. Eight implants scored bone loss up to 3, four up to 4 and one up to 5. Five implants were lost.