T. Page et al., SIMPLE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY QUANTITATION OF GANCICLOVIR IN HUMAN SERUM AND URINE, Journal of chromatography B. Biomedical applications, 675(2), 1996, pp. 342-346
Citations number
8
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Journal title
Journal of chromatography B. Biomedical applications
A fast, simple, and cost-effective HPLC method for the quantitation of
the antiviral drug ganciclovir is described. The serum samples are ex
tracted with perchloric acid and neutralized with potassium phosphate
buffer, and urine samples are diluted with distilled water. A reversed
-phase column with isocratic elution by 15 mM potassium phosphate buff
er (pH 2.5) containing 0.25% acetonitrile is used to separate ganciclo
vir; quantitation is by UV absorbance at 254 nm. Total turnaround time
is 22 min; more than 3000 samples can be run on a single column witho
ut loss of peak quality. The limit of quantitation is 0.05 mu g/ml. Re
coveries varied from 91 to 107% with coefficients of variation ranging
from 0.387 to 7.95%.