Ne. Wijeysundera et al., ESTIMATION OF COLLECTOR PERFORMANCE PARAMETERS FROM DAILY SYSTEM TESTS, Journal of solar energy engineering, 118(1), 1996, pp. 30-36
A test procedure to estimate the daily mean values of the linear colle
ctor characteristics, F-R(tau alpha) and FRUL, from the measured varia
tion of the storage tank temperature was investigated The Levenberg-Ma
rquardt algorithm was used for parameter estimation. Two fiat-plate co
llectors were tested over a period of II days each to study the feasib
ility of the test procedure. The tests were conducted under variable w
eather conditions and infer water temperatures. The standard deviation
for the daily mean values of F-R(tau alpha) and FRUL were about 2.8 p
ercent and 4 percent, respectively. The differences between the daily
mean values obtained by the proposed method and the steady-state test
values for F-R(tau alpha) were about 4 percent to 7 percent, while for
FRUL the differences were 9 percent to 13 percent.