F. Vodopivec et al., SOLUBILITY OF (MNXFE1-X)S IN A 3-PERCENT SI STEEL WITHIN THE TEMPERATURE-RANGE 1100 TO 1300-DEGREES-C, Steel research, 67(2), 1996, pp. 67-72
By EPMA point counting the contents of sulphur and manganese in solid
solution were determined after annealing in a temperature range of 110
0 to 1300 degrees C and quenching in three 3% Si steels with 0.055 to
0.38% Mn. The established solubility products are not equal and differ
from published data.