LONG-TERM RESULTS OF VEIN GRAFTS INTERPOSED IN ARTERIAL DEFECTS USINGTHE TELESCOPING ANASTOMOTIC TECHNIQUE AND FIBRIN GLUE
Citation
S. Saitoh et Y. Nakatsuchi, LONG-TERM RESULTS OF VEIN GRAFTS INTERPOSED IN ARTERIAL DEFECTS USINGTHE TELESCOPING ANASTOMOTIC TECHNIQUE AND FIBRIN GLUE, Journal of hand surgery. British volume, 21B(1), 1996, pp. 47-52
Categorie Soggetti
Orthopedics,Surgery
SICI code
0266-7681(1996)21B:1<47:LROVGI>2.0.ZU;2-H
Abstract
Fibrin glue has been applied in the anastomosis of vein grafts placed
in rat femoral arteries using the telescoping technique at both ends o
f the graft. 34 out of 35 grafts which were patent 1 to 3 weeks post-o
peratively were kept for 3 months to assess the long-term patency, and
the effect of the glue on the diameters of the graft and femoral arte
ry, All 34 grafts were patent 3 months post-operatively. Excessive enl
argement of the graft diameter was alleviated by the fibrin glue witho
ut affecting the diameter of the femoral artery, The diameter at the p
roximal anastomosis was 66% and that at the distal anastomosis was 87%
of the diameter of the femoral artery.