It has been suggested that vibroacoustic stimulation might be stressfu
l to the fetus. The present study was designed to evaluate whether the
stimulus induces passage of meconium in labor. Patients in labor at t
erm with healthy fetuses and intact membranes were randomized to a vib
roacoustic stimulation or sham test. The incidence of meconium was the
same in both groups. Pregnancy outcome variables were also similar in
both groups. In conclusion, vibroacoustic stimulation does not increa
se the incidence of meconium passage in labor of healthy fetuses.