DETECTION OF DNA AND GLOBIN ADDUCTS OF POLYNUCLEAR AROMATIC HYDROCARBON DIOL EPOXIDES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND [H-3] CH3I POSTLABELING OF RELEASED TETRAOLS
Aa. Melikian et al., DETECTION OF DNA AND GLOBIN ADDUCTS OF POLYNUCLEAR AROMATIC HYDROCARBON DIOL EPOXIDES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND [H-3] CH3I POSTLABELING OF RELEASED TETRAOLS, Chemical research in toxicology, 9(2), 1996, pp. 508-516
Gas chromatography-negative ion chemical ionization mass spectrometry-
selected ion monitoring (GC-NICI-MS-SIM) was employed to detect tetram
ethyl ether derivatives of tetraols formed upon hydrolysis of DNA and
globin adducts derived from diol epoxides of benzo[a]pyrene (BP) and o
ther polynuclear aromatic hydrocarbons (PAH). The tetramethyl ether de
rivatives could also be detected by [H-3]CH3I postlabeling. The method
ology involves the following steps: (1) isolation of DNA or globin; (2
) mild acid hydrolysis under vacuum; (3) isolation of the resulting te
traols and derivatization to the corresponding tetramethyl ethers usin
g methyl sulfinyl carbanion and unlabeled or H-3-labeled CH3I; (4) ana
lysis by GC-NICI-MS-SIM or HPLC with radioflow detection. The optimum
conditions for hydrolysis of adducts and derivatization of the resulti
ng tetraols as well as the feasibility of this approach for detecting
PAH adducts in mice and humans were explored. Using the set of four BP
-tetraols that can be formed upon hydrolysis of adducts formed from ox
y-t-9,10-epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene (anti-BPDE) or oxy-c-
9,10-epoxy-7,8,9,10-tetrahydrobenzo[a]pyrene (syn-BPDE) as models, the
stability of the tetraols under the hydrolysis conditions was investi
gated. Adducts derived from anti-BPDE yield predominantly the stable -
10-tetrahydroxy-7,8,9,10-tetrahydrobenzo[a]pyrene (trans-anti-BP-tetra
ol), while adducts derived from syn-BPDE released cis-syn-BP-tetraol a
s a major hydrolysis product. Hydrolysis under vacuum significantly in
creased the recovery of tetraols. Conditions for derivatization of the
BP-tetraols as well as tetraols derived from several other PAH anti-d
iol epoxides were investigated. Tetramethyl ethers proved to be superi
or derivatives that were stable, easy to prepare in high yields, and d
etectable with high sensitivity by GC-NICI-MS-SIM (1-50 fmol per injec
tion). Alternatively, these derivatives could be detected by HPLC with
radioflow detection if [H-3]CH3I were employed for derivatization. Th
e methodology was tested by comparing levels of DNA and globin adducts
in mice treated with either unlabeled or H-3-labeled BP. Good agreeme
nt was obtained among the GC-NICI-MS-SIM, [H-3]CH3I postlabeling, and
conventional radiometric methods. Moreover, analysis of human hemoglob
in by GC-NICI-MS-SIM resulted in detection of adducts derived from ant
i-BPDE and -dihydroxy-t-3,4-epoxy-1,2,3,4-tetrahydrochrysene. The resu
lts of this study demonstrate that GC-NICI-MS-SIM of tetramethyl ether
s of tetraols formed by hydrolysis of PAH diol epoxide DNA and globin
adducts is a promising approach for detection and quantitation of addu
cts derived from a broad range of PAH.