M. Masar et al., SEPARATION OF SYNTHETIC FOOD COLORANTS BY CAPILLARY ZONE ELECTROPHORESIS IN A HYDRODYNAMICALLY CLOSED SEPARATION COMPARTMENT, Journal of chromatography, 724(1-2), 1996, pp. 327-336
Citations number
27
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Separation conditions enabling the complete resolution of eleven permi
tted synthetic food colourants and some of their subspecies by capilla
ry zone electrophoresis (CZE) were determined. Those conditions involv
e combining a suitable pH of the carrier electrolyte (pH 6.8) with hos
t-guest complexation effects of beta-cyclodextrin. A 300 mu m I.D. cap
illary tube made of fluorinated ethylene-propylene copolymer in a hydr
odynamically closed separation compartment was used for the CZE separa
tions. The capillary could accommodate 90-nl sample injection volumes,
thus providing limits of detection for the dyes of 11-300 ppb using a
photometric detector operating at a wavelength of 254 nm. R.S.D.s of
0.4-3.0% were typical for the determinations of the dyes present in sa
mples at 16 ppm concentrations. Erythrosine, exhibiting residual adsor
ption, gave more-scattered results under identical working conditions
(R.S.D. of ca. 9.0%). The utility of this rapid CZE procedure (migrati
on times of the dyes were 2.5-10.5 min) is illustrated for several pra
ctical samples, including soft drink concentrate and liqueur and monit
oring of the stability of aqueous solutions of indigo carmine.