NEW SYNCHRONIZATION METHOD FOR THYRISTOR POWER CONVERTERS TO WEAK AC-SYSTEMS

Citation
R. Weidenbrug et al., NEW SYNCHRONIZATION METHOD FOR THYRISTOR POWER CONVERTERS TO WEAK AC-SYSTEMS, IEEE transactions on industrial electronics, 40(5), 1993, pp. 505-511
Citations number
NO
Categorie Soggetti
Instument & Instrumentation","Engineering, Eletrical & Electronic
ISSN journal
02780046
Volume
40
Issue
5
Year of publication
1993
Pages
505 - 511
Database
ISI
SICI code
0278-0046(1993)40:5<505:NSMFTP>2.0.ZU;2-T
Abstract
This paper presents an improved approach to obtaining good zero voltag e crossing signals. These signals are subsequently used as synchroniza tion signals for a phase controlled thyristor power converter. Detecti on of accurate zero crossings are possible even under the following co nditions: large frequency changes, sudden load changes, and large comm utation overlap angles. The improved accuracy in the integrity of the zero crossing is obtained by reconstructing a voltage representing the ac source voltage . This voltage is determined from the distorted thy ristor converter input voltage, the converter input current, and an on line identification of the source impedance using a microcontroller-ba sed adaptive algorithm. The improvement provided by the new zero cross ing detection scheme is verified experimentally.