G. Ceccone et al., AN EVALUATION OF THE PARTIAL, TRANSIENT LIQUID-PHASE BONDING OF SI3N4USING AU COATED NI-22CR FOILS, Acta materialia, 44(2), 1996, pp. 657-667
Citations number
30
Categorie Soggetti
Material Science","Metallurgy & Metallurigical Engineering
The application of the partial transient liquid phase bonding (PTLPB)
process for joining silicon nitride ceramics using microdesigned Au/Ni
-Cr/Au multilayer interlayers has been investigated. The influence of
different bonding parameters, such as time, temperature and interlayer
thickness, on the microstructure and chemistry of the ceramic-metal i
nterfaces has been studied. Scanning electron microscopy and electron
probe microanalysis investigations revealed that the ceramics were bon
ded to the Ni-Cr foils by a thin CrN reaction product layer while the
Au had alloyed to form a Ni rich solid solution. Joints with room temp
erature average flexural strength of 272 MPa, were produced under opti
mized bonding conditions of 4 h at 1000 degrees C. These processing co
nditions resulted in joints with microstructure and strength equivalen
t to those obtained by optimized diffusion bonding procedures. The eff
ect of post-bonding annealing in air at 800 degrees C for 60 h on the
room temperature joint strength was also assessed.